Produkte/Ärztebedarf/Patientenmonitore
C90A Transport Monitor New generation of specialized transport monitor C90A is a Specialized transport monitor built on best quality ABS Plastic with And Shock Design so it can be used in Ambulance, patient Transport on Stretcher and ICU. It's More convenient in operation room for Laproscopic surgeries if used with twin combination of Masimo Spo2 & Etco2 (Respironics). It's a versatile design with First Aid kit bag, which make the patient transport more convenient with twin battery option. C90A has a built in battery of 4.4 AH and the first aid kit contains 2.6AH making C90A work for continous 8 hours. Features - 4.3 inch Color Touch Screen TFT, 1.2kg
- 2. With Dual Battery Option of 4.4 AH & backup support of 2.6 AH, Monitor can support up to 8 hours of continuous monitoring; making it suitable for transportation of patient in Ambulance
- 3. Flexible configuration to meet different clinical needs
- Real-time parameters measurement display
- Three level Audio and Visual Alarm
- Powerful storage capacity:
48 Hours trends graphic review 1000 sets NIBP data review 100 alarm records review - Real-time parameters measurement display with trends table
 | - Waterproof and Anti-shock desin
- Portable First Aid Bag for easy carrying of Patient Monitor and first aid kit
- Multiple carrying options: Shoulder/Stretcher/Ambulance
|  | - Can Exchange Data with C90 (Mother Unit)
- Can be used as a Module for C90 (ECG/SP02/NIBP/TEMP/RESP/C02)
|  | |  | - Comen Inherited feature of 9 common short cut keys
- Multiple interfaces
|  | - Two channel Waveform Display
|
Technical Specifications
Safety IEC6060M approved. CE marking according to MDD93/42/EEC Performance Specifications Display: 4.3 inch Color TFT touch screen Power Supply: 100-240 VAC. 50/60HZ Battery Type: Lithium-ion Voltage: 15VDC Capacitance 4.400 mAh Dimension: 85 mm(W) x 190mm (L) x 150 mm (H) Weight 1.2kg ECG Lead Type: 3-lead. 5-lead. 12-lead selectable ECG waveform: 2 channels Gain selection: x0.125; x0.25; xO 5; x1; x2; auto Sweep speed: 12.5mm/s, 25mm/s, 50mm/s Heart Rate range Adult: 15-300bpm; Neonate/ Pediatric 15-350bpm Accuracy: ±1bpm or ±1%.whichever is greater Alarm range: 15-350 bpm Respiration Method: Thoracic impedance Operation modes: Auto/Manual Measurement range: Adult 0-120 bpm; Neonate/Pediatric 0-150 bpm Alarm: YES, auditable and visual alarm, alarm events recallable NIBP Method: Automatic Oscillometric Operation modes: Manual/Automatic/Continuous Measurement types: Systolic, Diastolic, Mean Range of systolic pressure: Adult Mode 40 - 270 mmHg Pediatric Mode 40 - 200 mmHg Neonatal Mode 40 - 135 mmHg Range of diastolic pressure: Adult Mode 10 - 210 mmHg Pediatric Mode 10-l50mmHg Neonatal Mode 10-100 mmHg Range of mean pressure: Adult Mode 20 - 230mmHg Pediatric Mode 20-165mmHg Neonatal Mode 20 -110mmHg Accuracy: Max mean error 5 mmHg Max standard deviation 8 mmHg Resolution: 1mmHg COMEN SpO2 Measurement range: 0-100% Resolution: 1% Accuracy: ±2% (70-100%, Adult/Pediatric, non-motion) ±3% (70-100%, Neonate, non-motion) ±3% (70-100%, Adult/Pediatric/Neonate, motion) 0-69% unspecified Alarm range: 1-100% Masimo SpO2 (Optional) Measurement Accuracy: ±2% (70-100%, Adu/Ped, Non-motion) ±3% (70-100%, Neo, Non-motion) ±3% (70-100%, Motion) Nellcor SpO2 (Optional) Measurement Accuracy: ±2% (70-100%, MAX-A, MAX-AL, MAX-N, MAX-P, MAX-I and MAX-FAST sensors); ±3% (70-100%, D-ys, DS-100A, OXI-A/N and OXI-P/I sensors); 0-69% unspecified Puls rate Range: 0-254bpm Resolution: 1bpm Accuracy: ±3bpm Temperature Accuracy: ±0.1°C (Excluding the sensor) Measure range: 0-50°C Channel: Dual-channel, Provide T1; T2; Resolution: 0.1°C Respironics EtCO2
(Optional Sidestream/ Mainstream) Range: 0-150 mmHg Accuracy: ±2% 0-40 mmHg ±5% 41 -70 mmHg ±8% 71 - 100 mmHg ±10% 101 - 150 mmHg AwRR Accuracy: ±1rpm Convenient desgin for intubated and non-intubated applications Possible to work at low sample flow rate: 50ml/min Convenient operation / Data Configuration | ECH/HR | SPO2/PR | NIBP | TEMP | RESP | EtCO2 | C90A (SpO2) | X | V | X | X | X | X | C90A (SpO2+NIBP) | X | V | V | X | X | X | C90A (ECG+SpO2) | V | V | X | X | X | X | C90A (ECG+SpO2+NIBP) | V | V | V | X | X | X | C90A (SpO2+ETCO2) | X | V | X | X | X | V | C90A (ECG+SpO2+ETCO2) | V | V | X | X | X | V | C90A (ECG+SpO2+NIBP+TEMP+RESP) | V | V | V | V | V | X |
|