products/Clinical Chemistry/Analytical systems/BGT-KC400
BGT-KC400Auto Chemistry Analysator System function Throughput: up to 450 tests/Hour(not including ISE tests) Test Method: End point, Fixed time, Kinetic Test Sequence: Discrete, Random access, STAT can be inserted at any time. Test sequence can be sorted by samples or items Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free. Cuvette washing: auto wash the cuvettes through 6 segments washing pipe and continuous usethem, and each cuvette wash 12 times before use it again. Reaction detect: monitor 81 cuvettes's reaction at the same time Photometric process: the interval time between two consecutive photometric points are exactly the same. Pipeline system: pressure auto released pumps and double filters to protect pumps and valves Gearing: plastic gear leads lower noise and accuracy of positioning of moving parts Environmental resistance: resistant form dust and water vapor Sample/Reagent/Stirrer system Sample volume: 2µL-30µL. step by 0.1µL Sample disc: 60 positions for primary tubes and secondary cups Sample probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and vertical and horizontal collision protection Sample tube: both primary tubes and secondary cups are suitable Reagent volume: 20µL-300µL, step by 1µL Reagent disc: provide 80 reagent bottle positions Reagent probe: inner and outer walls are highly polished leads carry-over <0.1%, level detectionand vertical and horizontal collision protection Reagent bottle: particular reagent bottle without dead volume Reagent Cooling: continuous cooling system according to the principle of peltier Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in. Water consume: <6L/hour Carry over: Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted Reaction system Cuvette: permanent UV free glass cuvette Reaction disc: Discal reaction disc with 81 disposable cuvettes Reaction volume: 150µL-600µL Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free Temperature: 37°C±0.1°C Optical system Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free Wavelength: 340nm. 405nm. 450nm, 510nm. 546nm. 578nm. 630nm. 670nm Absorbance range: 0-6
Calibration/QC Calibration type: single point linear, two points linear, multi-points linear, Logit-4P. Logit-5P. Spline. Exponential 5P. Polynomial 5P, auto choose the best fittest calibrationcurve. QC type: real time QC. daily QC. day to day QC QC chart: L-J, Cumulative sum check. Twin Plot QC rule: Customized QC rule in order to adapt different item's requirements
Operational system Operational system: VISTA, Windows XP, Windows2000 Memory: auto save and recover the results Report format: Customized report format Status Check: real time check the working status of the analyzer
Power/ Dimension Voltage: AC 85V - 264V, 55Hz±8Hz, Auto adapt according to the input voltage Power Consume: <550VA Dimension: 980mm x 712mm x 1100mm (L x W x H) Net weight: 160Kg

|